2.2. Upgrading Virtuozzo 6 with Virtuozzo Storage¶
This section describes how to upgrade your Virtuozzo Storage cluster based on Virtuozzo 6 to a Virtuozzo Storage cluster with CLI management based on Virtuozzo Hybrid Server 7. You can do this by using spare Virtuozzo 6 servers or in-place or migrate VMs and containers to a new Virtuozzo Storage cluster.
2.2.1. Upgrading with Spare Virtuozzo 6 Servers¶
Update all servers in the cluster based on Virtuozzo 6 to the latest version. You can do this by running
yum update
on each server.Note
The oldest Virtuozzo 6 build eligible for upgrade is 6.0.11-3466.
Choose a server to upgrade in the cluster and migrate VMs and containers from it to other Virtuozzo 6 servers in the cluster.
Remove chunk servers from the server:
Find out which chunk servers are stored on the server by running
pstorage -c <cluster_name> top
on any cluster server.Initiate removal of chunk servers from the server by running
pstorage -c <cluster_name> rm-cs --wait <CS_ID>
for each chunk server on the server.
Wait until the required chunk servers are removed and Virtuozzo Storage rebuilds. To monitor this process, run
pstorage -c <cluster_name> top
on any cluster server. The status of the chunk servers being removed will becomereleasing
and the number of replicas on them will start dwindling. When the number of replicas on a CS reaches zero, the CS will be removed both from the server and thepstorage top
output. Make sure that no chunk servers are left on the server to be upgraded.Perform a fresh install of Virtuozzo Hybrid Server 7 on the server. During installation, choose to create a new Virtuozzo Storage cluster. For instructions, see the Virtuozzo Hybrid Server 7 Installation Guide.
Choose another Virtuozzo 6 server in the old cluster and migrate VMs and containers from it to the new Virtuozzo Storage cluster based on Virtuozzo Hybrid Server 7. For details, see Migrating VMs and Containers from Virtuozzo 6 to Virtuozzo Hybrid Server 7.
If you have iSCSI targets on your Virtuozzo Storage cluster based on Virtuozzo 6, move them to the new Virtuozzo Storage cluster based on Virtuozzo Hybrid Server 7. For details, see Moving iSCSI Targets between Virtuozzo Storage Clusters.
Perform a fresh install of Virtuozzo Hybrid Server 7 on the second server. During installation, choose to join the new Virtuozzo Storage cluster based on Virtuozzo Hybrid Server 7. For instructions, see the Virtuozzo Hybrid Server 7 Installation Guide.
Repeat steps 6-8 for the remaining servers in the old cluster until all Virtuozzo 6 servers are upgraded to Virtuozzo Hybrid Server 7.
If you store VM and container backups on a Virtuozzo 6 server, move them to a Virtuozzo Hybrid Server 7 server as described in Restoring Virtuozzo 6 Backups to Virtuozzo Hybrid Server 7.
2.2.2. Upgrading by Migrating to a New Virtuozzo Storage Cluster¶
To upgrade by migrating VMs and containers from an old Virtuozzo Storage cluster based on Virtuozzo 6 to a new Virtuozzo Storage cluster based on Virtuozzo Hybrid Server 7, do the following:
Update all servers in the cluster based on Virtuozzo 6 to the latest version. You can do this by running
yum update
on each server.Note
The oldest Virtuozzo 6 build eligible for upgrade is 6.0.11-3466.
On a different set of servers, create a new Virtuozzo Storage cluster based on Virtuozzo Hybrid Server 7. For instructions, see the Virtuozzo Hybrid Server 7 Installation Guide.
Migrate VMs and containers from the old cluster to the new cluster. For more details, see Migrating VMs and Containers from Virtuozzo 6 to Virtuozzo Hybrid Server 7.
If you have iSCSI targets on your Virtuozzo Storage cluster based on Virtuozzo 6, move them to the new Virtuozzo Storage cluster based on Virtuozzo Hybrid Server 7. For details, see Moving iSCSI Targets between Virtuozzo Storage Clusters.
If you store VM and container backups on a Virtuozzo 6 server, move them to a Virtuozzo Hybrid Server 7 server as described in Restoring Virtuozzo 6 Backups to Virtuozzo Hybrid Server 7.
2.2.3. Upgrading In-Place with Virtuozzo Storage¶
Virtuozzo 6 hardware nodes in a Virtuozzo Storage cluster can be upgraded in-place to Virtuozzo Hybrid Server 7 as follows:
Update all servers in the cluster to the latest version of Virtuozzo 6. You can check versions on all cluster nodes with
pstorage -c <cluster_name> stat
.Note
The oldest Virtuozzo 6 build eligible for upgrade is 6.0.11-3466.
Add at least two spare Virtuozzo Hybrid Server 7 servers to the cluster to ensure high availability of virtual environments that will be hosted on the upgraded Virtuozzo Hybrid Server 7 servers. To do this, perform a fresh install of Virtuozzo Hybrid Server 7 on two or more servers. During installation, choose to join your Virtuozzo Storage cluster and tick the checkbox for the Client Server Role that will automatically enable HA for virtual machines and containers registered on the server. For more details, see Joining an Existing Virtuozzo Storage Cluster.
Important
After you update the last node with the MDS server to Virtuozzo Hybrid Server 7, you will not be able to create or re-create Virtuozzo 6 MDS servers. In addition, you will not be able to use Virtuozzo 6 CS servers or clients (cluster mountpoints on Virtuozzo 6 nodes) in a cluster without Virtuozzo 6 MDS servers.
If you have iSCSI targets registered on the Virtuozzo 6 server, stop and unregister them from the server before the upgrade. For example, for the target
iqn.2014-04.com.pstorage:test1
run:# pstorage-iscsi stop -t iqn.2014-04.com.pstorage:test1 # pstorage-iscsi unregister -t iqn.2014-04.com.pstorage:test1
If you have virtual machines on the Virtuozzo 6 server, migrate them to the newly added Virtuozzo Hybrid Server 7 servers as described in Migrating VMs and Containers from Virtuozzo 6 to Virtuozzo Hybrid Server 7.
Upgrade each cluster node, one at a time, to Virtuozzo Hybrid Server 7 as described in Upgrading In-Place with Local Storage.
Re-register the iSCSI targets and restart them on the upgraded Virtuozzo Hybrid Server 7 server. For example, for the target
iqn.2014-04.com.pstorage:test1
run:# vstorage-iscsi register -t iqn.2014-04.com.pstorage:test1 # vstorage-iscsi start -t iqn.2014-04.com.pstorage:test1
When only three Virtuozzo 6 servers are left to upgrade, migrate all virtual environments from them to the upgraded Virtuozzo Hybrid Server 7 servers. For more details, see Migrating VMs and Containers from Virtuozzo 6 to Virtuozzo Hybrid Server 7.
Repeat step 5 for the remaining servers until all Virtuozzo 6 servers are upgraded to Virtuozzo Hybrid Server 7.
If at some point your cluster happens to be populated with both Virtuozzo 6 and Virtuozzo Hybrid Server 7 hardware nodes, it will retain the functionality of Storage for Virtuozzo 6 but not gain the new features of Storage for Virtuozzo Hybrid Server 7 like erasure coding. As soon as the last Virtuozzo 6 MDS server is removed and the total count of Virtuozzo Hybrid Server 7 MDS servers reaches three, the cluster will begin operating with complete functionality offered by Storage for Virtuozzo Hybrid Server 7.
Note
Even though Virtuozzo Storage supports mixed clusters, it is recommended to eventually upgrade all nodes in the cluster to Virtuozzo Hybrid Server 7.