Virtuozzo Hybrid Server 7.5 Update 5 (7.5.5-249)¶
Issue date: 2023-07-27
Applies to: Virtuozzo Hybrid Server 7.5
Virtuozzo Advisory ID: VZA-2023-021
1. Overview¶
Virtuozzo Hybrid Server 7.5 Update 5 introduces new features and provides stability and usability bug fixes. Additionally, it provides a new kernel 3.10.0-1160.90.1.vz7.200.7.
2. New Features¶
Now, the default EFI flash size in virtual machines is 4 MB for newly created virtual machines. (PSBM-144916)
Virtual machines with EFI are automatically converted to a 4-MB flash size. (PSBM-144916)
Updated Windows guest drivers. (PSBM-146201)
Updated Virtuozzo Storage packages to the latest version. (PSBM-146257)
Improvements in CRIU—a major version update to criu-3.18. (PSBM-147172)
3. Bug Fixes¶
Live migration of Windows 2008 Server R2 virtual machines between Virtuozzo Hybrid Server 7.5 Update 4 nodes could fail. (PSBM-148279)
Improved behavior for the ‘prlctl move’ command when moving data between datastores in Virtuozzo Storage. (PSBM-147476)
A container backup could fail when the ‘VZ_TOOLS_IOLIMIT’ parameter in ‘/etc/vz/vz.conf’ was uncommented. (PSBM-147036)
After updating a node to Virtuozzo Hybrid Server 7.5 Update 4, the dispatcher service could fail to start. (PSBM-146558)
Failure to configure DNS settings in a newly created Ubuntu 20.04 container. (PSBM-146303)
A container live migration could fail with an nft rules error. (PSBM-145429)
The installation of the KB5012170 Windows update for VZ7 Windows Server 2016 and 2019 virtual machines could fail. (PSBM-143808)
The VPS filesystem could run out of space when running ‘pcompact’ on the host node. (PSBM-143781)
Failure to sync containers’ statuses between the dispatcher and virsh. (PSBM-141633)
Under specific circumstances, a host could get a per-CPU memory leakage. (PSBM-141114, PSBM-145276, PSBM-145270)
Other fixes. (PSBM-148636, PSBM-148420, PSBM-148346, PSBM-148336, PSBM-148283, PSBM-148052, PSBM-147601, PSBM-147193, PSBM-146883, PSBM-146842, PSBM-145018)
4. Known Issues and Limitations¶
The migration of EFI virtual machines to the previous versions of Virtuozzo Hybrid Server (Virtuozzo Hybrid Server 7.5 Update 4 and earlier) is not allowed due to the EFI flash size change.
Due to the EFI flash size change, backups of EFI virtual machines created on a Virtuozzo Hybrid Server 7.5 Update 5 host work improperly if restored in the previous versions of Virtuozzo Hybrid Server (Virtuozzo Hybrid Server 7.5 Update 4 and earlier).
EFI virtual machines running the Ubuntu and Debian guest OSs, with heavily modified EFI settings, may require a manual boot recovery after the EFI flash size change.
Starting from Virtuozzo Hybrid Server 7.5 Update 5, the fast path option cannot be turned off. The ‘fuse_kio_pcs’ fast path module is now a prerequisite for the ‘vstorage-mount’ service and cannot be unloaded on the nodes where Virtuozzo Storage is mounted. (PSBM-146257)
Experimental support of the Almalinux 9.2 guest operating system in virtual machines.
Acronis Notary cannot get the certificate. (PSBM-148315)